The minimum egress window opening is 20 wide.
Basement bedroom egress window requirements ontario.
Egress windows must be more than 1 5 feet ca.
The minimum opening area of the egress window is 5 7 square feet.
An emergency escape requires that each bedroom must have a door that leads directly to.
Certainly it is one option for meeting the egress requirements but it is possible to meet the requirements via windows and or doors outside the bedroom in some cases if they meet certain specifications.
It must be at least 5 7 square feet that is at least 20 inches wide by 24 inches high with an opening no higher than 44 inches from the floor.
The ontario building code egress windows or doors for bedrooms.
1 except where a door on the same floor level as the bedroom provides direct access to the exterior every floor level containing a bedroom in a suite shall be provided with at least one outside window that a is openable from the inside without the use of tools.
The report also notes.
When a door is being used to meet the egress requirements it must be either a side hinged door or a slider.
In addition the egress window requirements for basements specifies that they be at least 36 inches in height and width with a fully functioning opening.
Additional requirements of egress style windows.
Emergency egress window requirements for bedrooms.
Egress window s or door s for bedrooms.
What might surprise you the most is that the fire code does not necessarily require a window in the bedroom itself.
You must be able to do so without the use of additional tools or complicated instructions.
There are still light and ventilation requirements that must be met.
Light at least five per cent of the floor area served ventilation at least 0 28m or 3 ft or an adequate year round mechanical ventilation emergency escape.
The egress window must have a glass area of not less than 8 of the total floor area of room s for which it is servicing to allow the minimum amount of sufficient natural light.
The minimum egress window opening height is 24 high.
Egress basement windows are required by law to have some sort of step stairs underneath to provide a safe easy escape route during an emergency.
Basement egress windows must have window wells that are 760m from the window and opening of 30 inches deep.
In any ontario home the natural ventilation provided by a window opening must be equal or greater to 3 sqft can also be created mechanically.
Also note that if a window is being used to meet the egress requirements in addition to the above the sill height of the window shall not be more than 44 inches above the finished floor.
Requirements of the basement egress window.
Installed security bars on basement or bedroom egress windows must be able to be easily removed from inside the home.