Toilet room fixtures and accessories.
Ada grab bar height toilet.
Top of grab bar gripping surface 17 18 figure 11b 604 7 dispenser outlet location figure 11b 604 5 1 side wall grab bar at water closets figure 11b 604 5 2 rear wall grab bar at water closets these diagrams illustrate the specific requirements of these regulations and are intended only as an aid for building design and construction.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
Refer ada section 609 4.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Normally grab bars that are fastened to the wall by a toilet are placed at a height of 33 to 36 inches that s 840 to 915 mm.
Draw a pencil line along the.
2 the height of water closets should be between 11 17 to the top of the seat 3 the outlet of the toilet paper dispensers should not be mounted lower than 14 and no higher than 19 4 the top of the gripping surface at grab bars for children should be mounted between 18 27 a f f.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.
Grab bars 1 1 4 o 1 1 2 o mounted at 33 above floor with 1 1 2 wall clearance.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
19 water closet flush control max.
Ada specifies that grab bars must be positioned between 33 and 36 inches above the floor so centering the bar at 34 5 inches ensures you will fall within this range.
The height of the toilet seat shall be 17 to 19 inches 430 485 mm above the finished floor.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Grab bars enlarging toilet stalls insulating pipes or installing accessible faucet controls.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
Water closet height min.